Mitsubishi Electric FR-A700 Instruction Manual page 630

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Communication operation and setting
● Communication request data from the computer to the inverter
Format
(Data write)
(Data write)
(Data read)
● Reply data from the inverter to the computer when data is written
Format
(No data error
detected)
(Data error
detected)
● Reply data from the inverter to the computer when data is read
Format
(No data error
detected)
(No data error
detected)
(Data error
detected)
● Send data from the computer to the inverter during data read
Format
(No data error
detected)
(Data error
detected)
Indicate a control code (Refer to Tab. 6-135.)
Specify the inverter station numbers between H00 and H1F (stations 0 to 31) in hexadecimal.
When Pr. 123, Pr. 337 "Waiting time setting" ≠ 9999, create the communication request data
without "waiting time" in the data format. (The number of characters decreases by 1.)
CR, LF code
When data is transmitted from the computer to the inverter, CR (carriage return) and LF
(line feed) codes are automatically set at the end of a data group on some computers. In
this case, setting must also be made on the inverter according to the computer. Whether
the CR and LF codes will be present or absent can be selected using Pr. 124 or Pr. 341
"CR, LF presence/absence selection".
6 - 450
1
2
Inverter
A
ENQ
station
number
Inverter
A'
ENQ
station
number
Inverter
B
ENQ
station
number
Number of Characters
1
2
C
Inverter
ACK
station
number
D
Inverter
NAK
station
number
1
2
E
Inverter
STX
station
number
E'
Inverter
STX
station
number
D
Inverter
NAK
station
number
Number of Characters
1
2
C
Inverter
ACK
station
number
F
Inverter
NAK
station
number
Number of Characters
3
4
5
6
Waiting
Instruction
code
time
Waiting
Instruction
code
time
Waiting
Instruction
Sum check
code
time
3
4
5
Error
code
Number of Characters
3
4
5
6
Read data
Read data
ETX
Sum check
Error
code
3
4
7
8
9
10
Data
Sum check
Data
Sum check
7
8
9
10
ETX
Sum check
Parameter
11
12
13
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a740 ecFr-a700 ec

Table of Contents