Parameter
Current monitoring reference (Pr. 56)
Set the current to be referenced when the current monitor (inverter output current, etc.) is
selected for the terminal CA and terminal AM display.
● Set the current value when the current output at terminal CA is 20mA DC. The analog current
output at terminal CA and the current value are proportional. (The maximum output current
is 20mA DC.)
● Set the current value when the voltage output at terminal AM is 10V DC. The analog voltage
output at terminal AM and the current value are proportional. (The maximum output voltage
is 10V DC.)
10V DC/
20mA DC
Torque monitoring reference (Pr. 866)
Set the current to be referenced when the torque monitor is selected for the terminal CA and ter-
minal AM display.
● Set the current value when the current output at terminal CA is 20mADC. The analog current
output at terminal CA and the current value are proportional. (The maximum output current
is 20mADC.)
● Set the current value when the voltage output at terminal AM is 10VDC. The analog voltage
output at terminal AM and the current value are proportional. (The maximum output voltage
is 10VDC.)
10V DC/
20mA DC
FR-A700 EC
500A
Rated output current
(3600A)
(initial value)
Setting range of Pr. 56
400 %
150 %
(Initial value)
Setting range of Pr. 866
Monitor display and monitor output signals
Fig. 6-149:
Current monitoring reference
Fig. 6-150:
Torque monitoring reference
I001165E
I001598E
6 - 331