Mitsubishi Electric FR-A700 Instruction Manual page 652

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Communication operation and setting
Example
To read the register values of 41004 (Pr. 4) to 41006 (Pr. 6) from the slave address 17
(H11).
Query message
Slave Ad-
dress
H11
(8 bit)
Normal response (Response message)
Slave Ad-
dress
H11
(8 Bit)
Read value:
Register 41004 (Pr. 4): H1770 (60.00Hz)
Register 41005 (Pr. 5): H0BB8 (30.00Hz)
Register 41006 (Pr. 6): H03E8 (10.00Hz)
6 - 472
Function
Starting Address
H03
H03
(8 bit)
(8 bit)
Byte
Function
Count
H03
H06
H17
(8 Bit)
(8 Bit)
(8 Bit)
No. of Points
HEB
H00
(8 bit)
(8 bit)
Data
H70
H0B
HB8
(8 Bit)
(8 Bit)
(8 Bit)
Parameter
CRC Check
H03
H77
(8 bit)
(8 bit)
CRC Check
H03
HE8
H2C
(8 Bit)
(8 Bit)
(8 Bit)
H2B
(8 bit)
HE6
(8 Bit)