Parameter
6.5.2
Conditional position feed function by contact input
(Pr. 419, Pr. 464 to Pr. 494)
Inputting the number of pulses (positions) in the parameters and setting multi-speed (refer to
page 6-132) and forward (reverse) commands enable position control. The motor does not
return to the home position with this conditional position feed function.
Pr.
Name
No.
Position command
419
source selection
Digital position
464
control sudden stop
deceleration time
FR-A700 EC
Initial
Setting Range
Description
Value
Conditional position control func-
0
tion by contact input. (position
command by parameter settings)
0
Conditional pulse train position
2
command by inverter pulse train
input
Set the time until the inverter stops
when the forward rotation (reverse
0 s
0–360,0 s
rotation) command is turned off
with the position feed forward func-
tion.
Vector
Vector
Vector
Position control by vector control
Parameters referred to
20
Acceleration/decel-
eration reference
frequency
29
Acceleration/decel-
eration pattern
selection
Refer to
Section
6.11.1
6.11.3
6 - 131