Parameter
Energy saving monitor list
The following table provides the items that can be monitored by the power saving monitor
(Pr. 52 = Pr. 54 = Pr. 158 = 50). (Only
can be output to Pr. 54 (terminal CA) and Pr. 158 (terminal AM)).
Energy Sav-
ing Monitor
Item
Power saving
Power
saving rate
Power
saving
average
value
Power
saving rate
average
value
Power
savings
amount
average
value
Tab. 6-100: Power saving monitor list
FR-A700 EC
Description and Formula
Difference between the estimated value of
power necessary for commercial power supply
operation and the input power calculated by the
inverter
Power during commercial power supply opera-
tion − input power monitor
Ratio of power saving on the assumption that
power during commercial power supply opera-
tion is 100%
Power saving
×
------------------------------------------------------------------ -
100
Power during commercial
power supply operation
Ratio of power saving on the assumption that
Pr. 893 is 100%
Power saving
×
----------------------------------------- -
100
Pr. 893
Average value of power saving amount per
hour during predetermined time (Pr. 897)
Σ
(
×
Δt
)
Power saving
------------------------------------------ -
Pr. 897
Ratio of power saving average value on the
assumption that the value during commercial
power supply operation is 100%
Σ
(
×
Δt
)
Power saving rate
----------------------------------------------------------------------------
Pr. 897
Ratio of power saving average value on the
assumption that Pr. 893 is 100%
Power saving average value
---------------------------------------------------------------------------------- -
Pr. 893
Power saving average value represented in
terms of charge
Power saving average value
Energy saving operation and energy saving monitor
"Power saving" and
Unit
0.01kW/
0.1kW
0.1%
0.01kW/
0.1kW
×
100
0.1%
×
100
0.01/0.1
×
Pr. 896
"Power saving average value"
Parameter Setting
Pr. 895 Pr. 896 Pr. 897 Pr. 899
9999
9999
0
1
9999
9999
0
0
to
1000h
1
0
to
500
6 - 361