Mitsubishi Electric FR-A700 Instruction Manual page 224

Frequency inverter
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
292
Refer to Pr. 61
293
294
Refer to Pr. 261
299
Refer to Pr. 57
331
Refer to Pr. 117
337
Communication opera-
338
tion command source
Communication speed
339
command source
NET mode operation
command source
550
selection
PU mode operation
command source
551
selection
340
Refer to Pr. 79
341
Refer to Pr. 117 to Pr. 124
343
Tab. 6-1:
Parameter overview (44)
6 - 44
Incre-
Initial
Setting
ments
Value
Range
0
1
0
1
0
1
1
0
2
0
1
1
9999
9999
1
1
2
2
3
Description
Operation command source
communication
Operation command source exter-
nal (start/stop)
Speed command source
communication
Speed command source external
(Frequency setting from commu-
nication is invalid, terminal 2 and 1
setting from external is valid)
Speed command source external
(Frequency setting from commu-
nication is valid, terminal 2 and 1
setting from external is invalid
Communication option valid
Inverter RS-485 terminal valid
Automatic recognition of the com-
munication option
Normally, the RS-485 terminals
are valid. Communication option is
valid when the communication
option is mounted
Select the RS-485 terminals as the
PU operation mode control
source.
Select the PU connector as the PU
operation mode control source.
Select the USB connector as the
PU operation mode control
source.
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-429