Parameter
Parameter
Func-
Name
tion
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal func-
195
tion selection
ABC2 terminal func-
196
tion selection
Tab. 6-1:
Parameter overview (37)
FR-A700 EC
Incre-
Initial
Setting
ments
Value
Range
1
0
1
1
0–5/7/8/
10–19/25/
26/45–47/
64/70–78/
90–96/
98/99/
100–105/
1
2
107/108/
110–116/
125/126/
145–147/
164/170/
190–196/
198/199/
9999
1
3
1
4
0–5/7/8/
1
99
10–19/25/
26/45–47/
64/70–78/
90/91/
94–96/
98/99/
100–105/
107/108/
110–116/
125/126/
145–147/
164/170/
190/191/
1
9999
194–196/
198/199/
9999
Description
0/100: Inverter running
1/101: Up to frequency
2/102: Instantaneous power
failure/under voltage
3/103: Overload alarm
4/104: Output frequency
detection
5/105: Second output frequency
detection
6/106: Third output frequency
detection
7/107: Regenerative brake
prealarm (≥ 01800)
8/108: Electronic thermal relay
function prealarm
10/110: PU operation mode
11/111: Inverter operation ready
12/112: Output current detection
13/113: Zero current detection
14/114: PID lower limit
15/115: PID upper limit
16/116: PID forward/reverse
rotation output
17/–:
Commercial power-
supply switchover MC1
18/–:
Commercial power-
supply switchover MC2
19/–:
Commercial power-
supply switchover MC3
20/120: Brake opening request
25/125: Fan fault output
26/126: Heatsink overheat
prealarm
27/127: Orientation in-position *
28/128: Orientation error *
30/130: Forward rotation output *
31/131: Reverse rotation output *
32/132: Regenerative status
output *
33/133: Operation ready 2
34/134: Low speed output
35/135: Torque detection
36/136: In-position *
39/139: Start time tuning completion
41/141: Speed detection
42/142: Second speed detection
43/143: Third speed detection
44/144: Inverter running 2
45/145: Inverter running and start
command is on
46/146: During deceleration at
occurrence of power fail-
ure (retained until release)
47/147: PID control activated
64/164: During retry
70/170: PID output interruption
84/184: Preparat DC current feed-
ingion ready signal *
85/185: DC current feeding
90/190: Life alarm
91/191: Alarm output 3
(power-off signal)
92/192: Energy saving average
value updated timing
93/193: Current average monitor
94/194: Alarm output 2
95/195: Maintenance timer alarm
96/196: Remote output
97/197: Minor fault output 2
98/198: Minor fault output
99/199: Alarm output
9999:
No function
0–99:
Source logic
100–199: Sink logic
* Available only when used with
the FR-A7AP
Parameter overview
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-298
6 - 37