Advertisement

Parameter
Tune second applied motor
● When you want to switch two motors with one inverter, set the second motor in Pr. 450
"Second applied motor" (refer to section 6.12.2). Initial setting is without second applied
motor.
● Turning the RT signal on makes the following parameters for the second parameters valid.
Function
Motor capacity
Number of motor poles
Motor excitation current
Motor rated voltage
Rated motor frequency
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)
Motor constant (L2)
Motor constant (X)
Auto tuning setting/status
Tab. 6-61: Validation of parameters by the RT signal
NOTES
The RT signal is assigned to the terminal RT in the initial setting. By setting "3" in any of Pr.
178 to Pr. 189 (input terminal function selection), you can assign the RT signal to the other
terminal.
Changing the terminal assignment using Pr. 178 to Pr. 189 "Input terminal function
selection" may affect other functions. Make setting after confirming the function of each
terminal.
FR-A700 EC
Selection and protection of a motor
RT Signal ON
(second motor)
Pr. 453
Pr. 454
Pr. 455
Pr. 456
Pr. 457
Pr. 458
Pr. 459
Pr. 460
Pr. 461
Pr. 462
Pr. 463
RT Signal OFF
(first motor)
Pr. 80
Pr. 81
Pr. 82
Pr. 83
Pr. 84
Pr. 90
Pr. 91
Pr. 92
Pr. 93
Pr. 94
Pr. 96
6 - 235