Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908
4.4.4.3 CR HP Sensor
1.
Remove the Control Panel.
(p203)
2.
Remove the IC Cover R and the IC Shaft Cover R.
3.
Remove the Maintenance Tank R.
4.
Remove the Right Cover.
(p209)
5.
Unlock the Carriage Unit.
(p201)
6.
Move the Carriage Unit to the location where the CR HP Sensor can be removed.
7.
Disengage the four hooks that secure the CR HP Sensor, and remove the CR HP
Sensor.
When disconnecting the connector in the next step, take care not to
C A U T I O N
push it inside the printer.
8.
Disconnect the connector from the CR HP Sensor.
DISASSEMBLY & ASSEMBLY
(p206)
(p208)
Disassembly and Assembly Procedure
- Right Side -
Connector
CR HP Sensor
Figure 4-61. Removing the CR HP Sensor
Revision I
Hook
239