ISSUE 2.0
Program Num-
ber
84-26-01
VoIP Basic Setup - IP Address
Assign the IP address that is used for Voice Communications
across the network. The IP address assigned here MUST be
within the same network as the IP address assigned in PRG
10-12-09.
90-10-01
System Alarm Setup - Alarm Type
Two Alarms were added for SL Net and they are:
Alarm 15 - Networking keep alive error
Alarm 59 - Networking port limit exceeded
90-10-02
System Alarm Setup - Report
This program is used to assign if the alarm is displayed on a
key telephone if the alarm information is reported to the pre-
defined destination.
Codec Assignment
Program Num-
ber
84-12-01
Networking CODEC Information Basic Setup - Number of
G.711 Audio Frames
84-12-02
Networking CODEC Information Basic Setup - G.711 VAD
mode
84-12-03
Networking CODEC Information Basic Setup - G.711 Type
84-12-04
Networking CODEC Information Basic Setup - G.711 Jitter
Buffer (min)
84-12-05
Networking CODEC Information Basic Setup - G.711 Jitter
Buffer (average)
84-12-06
Networking CODEC Information Basic Setup - G.711 Jitter
Buffer (max)
84-12-07
Networking CODEC Information Basic Setup - Number of
G.729 Audio Frames
84-12-08
Networking CODEC Information Basic Setup - G.729 VAD
mode
84-12-09
Networking CODEC Information Basic Setup - G.729 Jitter
Buffer (min)
Features and Specifications Manual
Program Name
Program Name
SL1100
Default
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.254.255.254
192.0.0.1 ~ 223.255.255.254
(default)
172.16.0.20
0 = No setting
1 = Major Alarm
2 = Minor Alarm
Refer to Programming Manual.
0 = No (alarm disabled)
1 = Yes (alarm enabled)
Refer to Programming Manual.
Default
1 = 10 ms
2 = 20 ms
3 = 30 ms
4 = 40 ms
(default)
3
0 = Disable
1 = Enable
(default)
0
0 = A-law
1 = μ-law
(default)
1
0 ~ 255 ms
(default)
30
0 ~ 255 ms
(default)
60
0 ~ 255 ms
(default)
120
1 = 10 ms
2 = 20 ms
3 = 30 ms
4 = 40 ms
5 = 50 ms
6 = 60 ms
(default)
3
0 = Disable
1 = Enable
(default)
0
0 ~ 255 ms
(default)
30
S