Siemens SINAMICS S120 Function Manual page 253

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

● p2248[0...n] Technology controller motorized potentiometer, ramp-down time
● r2250 CO: Technology controller motorized potentiometer, setpoint after RFG
Closed-loop control
● p2200 BI: Technology controller enable
● p2253[0...n] CI: Technology controller setpoint 1
● p2254 [0...n] CI: Technology controller setpoint 2
● p2255 Technology controller setpoint 1 scaling
● p2256 Technology controller setpoint 2 scaling
● p2257 Technology controller ramp-up time
● p2258 Technology controller ramp-down time
● p2261 Technology controller setpoint filter time constant
● p2263 Technology controller type
● p2264[0...n] CI: Technology controller actual value
● p2265 Technology controller actual value filter time constant
● p2280 Technology controller proportional gain
● p2285 Technology controller integral action time
● p2289[0...n] CI: Technology controller pre-control signal
p2295 Technology controller output scaling
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Function modules
7.2 Technology controller
253