12.13 System sampling times
12.13.2

Setting the sampling times

Introduction
Setting the sampling times via p0112
The sampling times for:
● Current controller (p0115[0])
● Speed controller (p0115[1])
● Flux controller (p0115[2])
● Setpoint channel (p0115[3])
● Position controller (p0115[4])
● Positioner (p0115[5])
● Technology controller (p0115[6])
are set by selecting the appropriate values in p0112 for the closed-loop control configuration
and are copied to p0115[0...6] depending on the performance levels required. The
performance levels range from xLow to xHigh.
The sampling times are shown in the following table.
Table 12- 22 For Active Infeed, the sampling time is set using p0112 (p0112 = 1 not for p0092 = 1)
p0112
p0115[0]
1: xLow
400
2: Low
250
3: Standard
125
4: High
125
5: xHigh
125
Table 12- 23 For Smart Infeed, the sampling time is set using p0112 (p0112 = 1 not for p0092 = 1)
p0112
p0115[0]
1: xLow
400
2: Low
250
3: Standard
250
4: High
250
5: xHigh
-
Table 12- 24 For Basic Infeed Booksize, the sampling time is set using p0112
p0112
p0115[0]
1: xLow
-
2: Low
-
3: Standard
-
630
p0115[1]
p0115[2]
-
-
-
-
-
-
-
-
-
-
p0115[1]
p0115[2]
-
-
-
-
-
-
-
-
-
-
p0115[1]
p0115[2]
-
-
-
-
-
-
p0115[3]
p0115[4]
1600
-
2000
-
2000
-
1000
-
500
-
p0115[3]
p0115[4]
1600
-
2000
-
2000
-
1000
-
-
-
p0115[3]
p0115[4]
-
-
-
-
-
-
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
p0115[5]
p0115[6]
-
-
-
-
-
-
-
-
-
-
p0115[5]
p0115[6]
-
-
-
-
-
-
-
-
-
-
p0115[5]
p0115[6]
-
-
-
-
-
-