Siemens SINAMICS S120 Function Manual page 461

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

n_XIST2
Meaning
7
Abort get measured value •
8
Abort absolute value
transmission on
3841
Function not supported
Encoder 2 status word (G2_ZSW)
● See G1_ZSW (table 10-29)
Encoder 2 actual position value 1 (G2_XIST1)
● See G1_XIST1
Encoder 2 actual position value 2 (G2_XIST2)
● See G1_XIST2
Function diagrams (see SINAMICS S120/S150 List Manual)
● 4720 Encoder interface, receive signals, encoders n
● 4730 Encoder interface, send signals, encoders n
● 4735 Find reference mark with equivalent zero mark, encoders n
● 4740 Measuring probe evaluation, measured value memory, encoders n
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Adjustable parameter drive, CU_S parameter is marked
● p0418[0...15] Fine resolution Gx_XIST1
● p0419[0...15] Fine resolution Gx_XIST2
● p0480[0...2] CI: Signal source for encoder control word Gn_STW
● p0488[0...2] Measuring probe 1 input terminal
● p0489[0...2] Measuring probe 2 input terminal
● p0490 Invert measuring probe (CU_S)
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
More than one value requested
No value requested.
Requested value not available
Parking encoder active
Parking drive object active
Absolute encoder not available
Alarm bit absolute value protocol set
Communication PROFIBUS DP/PROFINET IO
10.1 Communication according to PROFIdrive
Possible causes / description
461

Advertisement

Table of Contents
loading

Table of Contents