Basic procedure
1. Create a request to write the parameters.
2. Invoke the request.
3. Evaluate the response.
Activity
1. Create the request.
Parameter request
Request header
1. parameter address
2. parameter address
3. parameter address
4. parameter address
4. parameter address
4. parameter address
1. parameter value(s)
2. parameter value(s)
3. parameter value(s)
4. parameter value(s)
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Request reference = 40
hex
Axis = 02 hex
Attribute = 10 hex
Parameter no. = 1055 dec
Subindex = 0 dec
Attribute = 10 hex
Parameter no. = 1056 dec
Subindex = 0 dec
Attribute = 10 hex
Parameter no. = 1058 dec
Subindex = 0 dec
Attribute = 10 hex
Parameter no. = 1059 dec
Subindex = 0 dec
Attribute = 10 hex
Parameter no. = 1059 dec
Subindex = 0 dec
Attribute = 10 hex
Parameter no. = 1059 dec
Subindex = 0 dec
Format = 07 hex
Value = 02D2 hex
Value = 0404 hex
Format = 07 hex
Value = 02D2 hex
Value = 0405 hex
Format = 08 hex
Value = 4396 hex
Value = 0000 hex
Format = 08 hex
Value = 4416 hex
Value = 0000 hex
Communication PROFIBUS DP/PROFINET IO
10.1 Communication according to PROFIdrive
Request ID = 02 hex
No. of parameters = 04 hex
No. of elements = 01 hex
No. of elements = 01 hex
No. of elements = 01 hex
No. of elements = 01 hex
No. of elements = 01 hex
No. of elements = 01 hex
No. of values = 01 hex
No. of values = 01 hex
No. of values = 01 hex
No. of values = 01 hex
Offset
0 + 1
2 + 3
4 + 5
6
8
10 + 11
12
14
16 + 17
18
20
22 + 23
24
26
22 + 23
24
26
22 + 23
24
26
28 + 29
30
32
34 + 35
36
38
40 + 41
42
44
46 + 47
48
50