Traversing Blocks - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.9.4

Traversing blocks

Description
Up to 64 different traversing tasks can be saved. The maximum number is set using
parameter p2615 (maximum number of traversing tasks). All parameters which describe a
traversing order are effective during a block change, i.e. if:
● The appropriate traversing block number is selected using binector inputs p2625 to
● A block change is made in a sequence of traversing tasks.
● An external block change p2632 "External block change" is triggered.
Traversing blocks are parameterized using parameter sets that have a fixed structure:
● Traversing block number (p2616[0...63])
● Task (p2621[0...63])
● Motion parameters
● Task mode (p2623[0...63])
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
p2630 (block selection, bits 0...5) and started using the signal at binector input p2531
(activate traversing task).
Every traversing block must be assigned a traversing block number (in STARTER "No.").
The traversing blocks are executed in the sequence of the traversing block numbers.
Numbers containing the value "-1" are ignored so that the space can be reserved for
subsequent traversing blocks, for example.
1: POSITIONING
2: FIXED ENDSTOP
3: ENDLESS_POS
4: ENDLESS_NEG
5: WAIT
6: GOTO
7: SET_O
8: RESET_O
9: JERK
– Target position or traversing distance (p2617[0...63])
– Velocity (p2618[0...63])
– Acceleration override (p2619[0...63])
– Deceleration override (p2620[0...63])
The execution of a traversing task can be influenced by parameter p2623 (task mode).
This is automatically written by programming the traversing blocks in STARTER.
Value = 0000 cccc bbbb aaaa
– aaaa: Display/hide
0000: Block is not hidden
0001: Block is hidden
A hidden block cannot be selected binary-coded via binector inputs p2625 to p2630.
An alarm is output if you attempt to do so.
– bbbb: Continuation condition
0000, END: 0/1 edge at p2631
0001, CONTINUE_WITH_STOP:
The exact position parameterized in the block is approached (brake to standstill and
positioning window monitoring) before block processing can continue.