Siemens SINAMICS S120 Function Manual page 445

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Bit
Meaning
Application:
This message indicates that the motor is overloaded and appropriate measures need to be taken to rectify the
situation (e.g. stop the motor or reduce the load).
2
|n_act| < p2161
Note:
The message is parameterized as follows:
p2161 Threshold value
p2150 Hysteresis
Application:
To protect the mechanics, the gear stages are not switched mechanically until the speed is less than the set
threshold value.
3
|n_act| ≤ p2155
Note:
The message is parameterized as follows:
p2155 Threshold value
p2140 Hysteresis
Application:
Speed monitoring.
4
Reserved
5
Variable signaling function
6
No motor overtemperature alarm
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Remarks
0
Torque utilization > p2194
The current torque utilization is greater than the
set torque utilization threshold (p2194).
1
|n_act| < p2161
The actual speed value is less than the set
threshold value (p2161).
0
|n_act| ≥ p2161
The actual speed value is greater than or the same
as the set threshold value (p2161).
1
|n_act| ≤ p2155
The actual speed value is less than or the same as
the set threshold value (p2155).
0
|n_act| > p2155
The actual speed value is greater than the set
threshold value (p2155).
1
The monitored signal of a SERVO axis has
exceeded the specified threshold value.
0
The monitored signal of a SERVO axis is within the
specified threshold value or the signaling function is
not active
1
No motor overtemperature alarm
The temperature of the motor is within the
permissible range.
0
Alarm, motor overtemperature
The temperature of the motor is greater than the set
motor temperature threshold (p0604).
Communication PROFIBUS DP/PROFINET IO
10.1 Communication according to PROFIdrive
BICO
BO: r2199.0
BO: r2197.1
BO: r3294
BO: r2135.14
445