Basic information about the drive system
12.1 Parameter
The CDS and DDS can be switched over during normal operation. Further types of data set
also exist, however these can only be activated indirectly by means of a DDS changeover.
● EDS Encoder Data Set
● MDS Motor Data Set
Figure 12-2
Saving parameters in a non-volatile memory
The modified parameter values are stored in the volatile RAM. When the drive system is
switched off, these data are lost.
The data must be saved retentively on the memory card, as described below, so that it is
available the next time the drive is switched on.