Siemens SINAMICS S120 Function Manual page 67

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Subject
Note:
The derating characteristics in the Equipment Manuals must be carefully observed!
Max. output frequency when using dv/dt and sine-wave filters 150 Hz!
Reaction in operation at the
thermal
limit of the motor
Speed setpoint
channel (ramp-function
generator)
Parallel connection of power
units
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Servo
Reduction in the
current setpoint or shutdown
Optional (reduces the number of
drives from 6 to 5 Motor
Modules with a sampling time
for current controller of 125
μs/speed controller 125 μs)
No
Servo control
2.9 Ramp-function generator
Vector
Reduction in the pulse
frequency and / or the current
setpoint or shutdown (not
applicable with parallel
connection / sine-wave filter)
Standard
Booksize:
No
Chassis:
Yes