Limitation of the speed controller output with dynamic speed limits
Figure 11-9
Parameters of the function diagram for torque limitation
p1551[0...n] Torque limit variable/fixed signal source / M_lim var/fixS_src
Sets the signal source for switching the torque limits between variable and fixed torque limit.
1 signal from BI: p1551:
A variable torque limit is effective (fixed torque limit + scaling).
0 signal from BI: p1551:
The fixed torque limit is effective.
p1552[0...n] Torque limit upper scaling without offset / M_max up offs scal
Sets the signal source for the scaling of the upper torque limit to limit the speed controller
output without considering current and power limits. A possible source is the torque preset
from the DCC diagram.
p1554[0...n] Torque limit lower scaling without offset / M_max low offsScal
Sets the signal source for the scaling of the lower torque limit to limit the speed controller
output without considering current and power limits. A possible source is the torque preset
from the DCC diagram.
Drive functions
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
r1538
r1534
p1552
r1535
p1554
r1539
Limitation of the speed controller output with dynamic speed limits (example of SERVO)
See 6060 for VECTOR application.
1
p1551
r0899.5
[5060 .4]
1
0
Applications
11.6 DCC axial winder
0
[5060 .7]
[5610.3]
r1509
+
[5060 .7]