Applications
11.3 Motor changeover
● 4 motor contactors with positively-driven auxiliary contacts (3 NC contacts, 1 NO contact)
● 4 motors, 1 Control Unit, 1 infeed, and 1 Motor Module
Figure 11-2
Table 11- 3
p0130
p0180
p0186[0...3]
p0820, p0821
p0822 to p0824
p0826[0...3]
p0827[0...3]
p0830.1 to
p0830.4
p0831[0...3]
p0833.0..2
Procedure for switchover between motor data sets
540
Example of motor changeover
Settings for the example
Parameter
Settings
4
4
0, 1, 2, 3
Digital inputs DDS
selection
0
1, 2, 3, 4
1, 2, 3, 4
Digital outputs, auxiliary
contactors
Digital inputs, auxiliary
contacts
0, 0, 0
Remark
Configure 4 MDS.
Configure 4 DDS.
The MDS are assigned to the DDS.
The digital inputs for motor changeover via DDS
selection are selected. Binary coding is used (p0820 =
bit 0 etc.).
Different numbers indicate a different thermal model
Assign the bit from p0830 to the MDS. If p0827[0] = 1,
for example, bit p0830.1 is set when MDS0 is selected
via DDS0.
The digital outputs for the auxiliary contactors are
assigned to the bits.
The digital inputs for the feedback signal of the motor
contactors are assigned.
The drive controls the contactor circuit and pulse
inhibition. Parking bit (Gn_ZSW14) is set.
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5