Description
2.14 Miscellaneous functions
-
-
-
These selection options correspond to the options that were previously available using
SD55613 $SCS_MEA_RESULT_DISPLAY.
Measurement result screen display and logging function can be separately activated and
deactivated. An additional CYCLE150 call should be programmed.
At the end of the program (channel RESET), the function is deactivated automatically, explicit
programming is not required.
Note
For compatibility reasons, the previous option of controlling the measurement result screen
display using setting data 55613 $SCS_MEA_RESULT_DISPLAY has been kept.
The measuring cycles can display different measuring result screens depending on the
measuring variant:
● Calibrating tool probes
● Tool measurement
● Calibrating workpiece probes
● Workpiece measurement
Content of measuring result screens
The measuring results screens contain the following data:
Calibrating the tool probe
● Measuring cycle and measuring variant
● Trigger values of axis directions and differences
● Probe number
● Safe area
Tool measurement
● Measuring cycle and measuring variant
● Actual values and differences for tool offsets
● Safe area and permissible dimensional difference
● T name, D number
58
"automatically 8 s" ...
"NC Start" ...
"for alarm" ...
The measurement result screen remains for a fixed time of 8 s
With the measurement result screen, the cycle is stopped using
M0, the measuring cycle is continued with NC Start and the
measurement result screen deselected
The measuring results screen is only displayed for cycle alarms
61303, 61304, 61305 and 61306.
Programming Manual, 12/2017, 6FC5398-4BP40-6BA1
Measuring cycles