Siemens SINUMERIK 840D sl Programming Manual page 86

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measuring variants
3.2 Measure workpiece (turning)
Starting position before the measurement
The probe must be positioned opposite to the calibration surface.
Position after the end of the measuring cycle
The probe (ball radius) is the distance of the measurement path away from the calibration
surface.
See also
Measuring the workpiece on a machine with combined technologies (Page 250)
Procedure
The part program or ShopTurn program to be processed has been created and you are in the
editor.
Parameters
G code program
Parameter
Description
Calibration data set (1 - 40)
F
Calibration and measuring fee‐
drate
86
1. Press the "Meas. workpiece" softkey.
2. Press the "Calibrate probe" softkey.
3. Press the "Radius on surface" softkey.
The input window "Calibrate: Radius at surface" opens.
ShopTurn program
Unit
Parameter
-
T
Distance/
D
min
F
β
X
Y
Z
Description
Name of the probe
Cutting edge number (1 - 9)
Calibration data set (1 - 40)
Calibration and measuring fee‐
drate
Tool alignment with swivel axis
(0 degrees)
(90 degrees)
● Value input
Start point X of the measure‐
ment
Start point Y of the measure‐
ment
Start point Z of the measure‐
ment
Programming Manual, 12/2017, 6FC5398-4BP40-6BA1
Unit
-
-
-
mm/min
Degrees
mm
mm
mm