Programming example:
CYCLE150(30,11012,"//NC/MPF.DIR/LAST_MEASURE.TXT")
M30
2.14.3.4
Standard log
Function
Standard logs display the results from measuring cycles in a clear log structure. The output is
possible in text or tabular format. Contents and structure are predefined.
Requirement
Standard logs are only possible in conjunction with measuring cycle calls.
Log contents
The logs are generally created with fixed English texts. (The measurement result displays
appear in the language that has been set for Operate.)
Logs of the measuring cycles have the following structures and contents:
● Header block - log header
– Date/time (when the log was created)
– Name and path of the log file
– Name of the part program from which the measuring function was called
– Workpiece number
● Value block - results per measuring point
– Number of the measuring point, measuring variant as programmed, time of the
– Specification of the correction target, either
– Setpoints, measured values, differences with specification of the respective axis name
Measuring cycles
Programming Manual, 12/2017, 6FC5398-4BP40-6BA1
measurement
Measuring variant as text (e.g. "1 hole")
measure only – no correction – or
for measuring variants with WO correction: Specification of the corrected WO, correction
target (WO / fine offset) – or
for measuring variants with tool offset: Tool name, D number, tool type, correction target
(length/radius, geometry/wear)
or measurement objects (e.g. "Diameter") and the measurement unit
1. Select Log "Last measurement" in the input field.
2. Supply additional parameters as described above.
3. Press the "Accept" softkey. The generated cycle call ap‐
pears in the editor.
Description
2.14 Miscellaneous functions
65