TEST NO. 2: Remote Hydraulics Relief Pressure

1. Make sure hydraulic oil is at normal operating temper-
ature before performing tests.
2. Raise and support dump box, if equipped, then en­
gage parking brake and stop the engine.
3. Install tester in series between pump outlet (pressure
hose) and dump valve. Make sure tester flow control
valve is open.
The engine must be running to perform hy­
draulic tests. To guard against possible per­
sonal injury, engage parking brake and keep
clothing, hands, feet, face and other parts of
the body away from fan or other moving parts.
4. Start the engine and operate at full speed (3,600
RPM). Leave tester flow control valve open. While
watching pressure gauges actuate and hold remote hy­
draulics control lever so oil flow goes over relief.
Hydraulic System
Install tester in
series between
pump outlet and
dump valve
CAUTION
Tester
Figure 11
Remote hydraulics
relief pressure
If unable to get specified pressure, check for:
– Worn or stuck relief valve.
– Internal leakage of remote cylinder(s).
Remote hydraulics
relief cartridge
Page 9 – 14
1,900 + 100 PSI
(13,100 + 690 kPa)
Figure 12