Oscillation
11.1 Asynchronous oscillation (OS, OSP1, OSP2, OST1, OST2, OSCTRL, OSNSC, OSE, OSB)
OSNSC
OSE
OSB
734
Define number of sparking-out strokes
Define end position (in workpiece coordinate system) to be approached after
deactivation of oscillation.
Note:
When programming OSE option 4 becomes effective implicitly for OSCTRL.
Define start position (in workpiece coordinate system) to be approached prior
to activation of oscillation.
The start position is approached before reversal point 1. If the start position
coincides with reversal position 1, reversal position 2 is approached next. No
stopping time applies when the start position is reached, even if this position
coincides with reversal position 1; instead, the axis waits for the exact stop fine
signal. Any exact stop condition configured is fulfilled.
Note:
Bit 9 in setting data SD43770 $SA_OSCILL_CTRL_MASK must be set to
initiate an approach to the start position.
Programming Manual, 06/2009, 6FC5398-2BP20-0BA0
Job Planning