5.6

KLC03 DC bus capacitor unit

5.6.1

KLC03 data sheet

Description
Mass
Allowed mounting position
Allowed input voltage
DC bus capacitance
Power dissipation at continuous
current and continuous DC bus power
respectively
Maximum discharge time from
U
to DC 50 V
R_DC_On
Allowed input current at L+ L-
Insulation resistance (at DC 500 V)
Technical data
Symbol
Unit
KLC03.1N-A04M7
m
kg
-
-
U
V
DC
C
mF
DC
P
W
Diss_cont
t
sec
entl_ZK
I
A
max(rms)
R
Mohm
is
Tab. 5-16:
KLC03 - technical data
Technical data of the components
KLC03.1N-B04M7
17
12
G1
G1, G2, G3, G4
DC 254 ... 750
4.7 ±20%
30
660
25
> 50