Kms; Required Steps To Follow; Preparations For Mounting; Mounting Kms - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

282/407
Mounting and installation
9.3

KMS

9.3.1

Required steps to follow

Preparations for mounting

Mounting KMS

Notes on mounting
Cold plate
Bosch Rexroth AG R911335703_Edition 04
Make the following preparations for mounting:
1. Procure tools, auxiliary materials, measuring and test equipment.
2. Check all components for visible damage. Defective components
mustn't be mounted.
3. Ensure that dimensions and tolerances on the installation side are
suitable for attachment (for details, see dimensional drawing).
4. Check whether all components, mounting surfaces and threads are
clean.
5. Ensure that mounting can be done in a dry and dust-free environment.
1.
To allow trouble-free servicing, make sure that the following aspects are
fulfilled after KSM has been mounted:
Connection points are easily accessible
Address selector switches are easily accessible
Diagnostic LED is visible
2.
Preferably mount the device to a conductive surface. If this is
impossible, later on connect the second connection point of equipment
grounding conductor at the device to the equipment grounding system
of the installation.
3.
For devices of the "W" and "A" cooling types, only the mounting position
G1 is allowed.
4.
For the dimensions of the mounting holes, see the dimensional drawing
of the device.
5.
Data of the mounting screws:
Devices of "B" or "I" cooling type:
Thread: M5
Tightening torque: 6 Nm
Devices of "A" or "W" cooling type:
Thread: M6
Tightening torque: 6 Nm
Devices of cooling type "B" are mounted on a cold plate.
Required cold plate properties:
See
chapter 9.1.3 "Cold plate" on page
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
279.

Advertisement

Table of Contents
loading