350/407
Commissioning, operation, diagnostics and maintenance
LED: Color / flashing pattern
Off
Flashing green
Green, lighting up once
Permanently lit green
Flashing red
Red, lighting up once
Red, lighting up twice
Bosch Rexroth AG R911335703_Edition 04
EtherCAT
Significance
1)
Status
INIT
Status
PRE-OPERATIONAL
Status
SAFE-OPERATIONAL
Status
OPERATIONAL
Configuration error
Synchronization error
Timeout - watchdog
1)
Flashing pattern: One square corresponds to a duration of
200 ms; the arrow marks the end of a cycle; abbreviations on
the squares: GN = LED permanently lit green, RD = LED per‐
manently lit red, -- = LED is off
Tab. 11-7:
Diagnostic LED
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
Description
Cyclic process data and acyclic data
channel are not transmitted
No error
Acyclic data channel is transmitted
Acyclic data channel is transmitted
Cyclic process data and acyclic data channel
are transmitted
General EtherCAT configuration error
The
drive
controller
synchronized to the EtherCAT master
Communication
error
controller
Timeout while cyclic process data are
monitored
Watchdog of the EtherCAT master
has
not
been
of
the
drive