Zone Setup; Safety Zones - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
7.1.10

Zone setup

Safety zones

Safety zone
A safety zone consists of a safety zone beginner and one or several safety
zone nodes. The example shows a drive system with 2 safety zones.
KCU, KSM 3
Safety zone beginner; alternative for KCU: KMV (S1
signal via X141 at KSM 1; KMV is not a safety zone
node)
KSM 1, KSM 4
Safety zone node
KSM 2
KSM without optional safety technology ⇒ not a safety
zone node
RBS0023
Connector for safety zone node at connection point
X141 (only required for KSM/KMS with optional safety
technology)
RKB0033
Cable for transmitting the safety-related signals
S 1, S 2
Signals of the individual safety zones
SI Zone 1, SI Zone 2 Safety zones
X49, X141
Connection points of safety technology
Fig. 7-18:
Safety zones
Notes on project planning