Knk03, Kmv03, Klc03; Arranging The Devices; Mounting; Electrical Connection - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

286/407
Mounting and installation
9.5

KNK03, KMV03, KLC03

9.5.1

Arranging the devices

9.5.2

Mounting

Notes on mounting
Cold plate
9.6

Electrical connection

9.6.1

General information

Bosch Rexroth AG R911335703_Edition 04
Mount the KMV supply unit to the left of the KNK mains filter. The connection
points at KMV then can be accessed and wired more easily.
1.
To allow trouble-free servicing, make sure that the following aspects are
fulfilled after KSM has been mounted:
Connection points are easily accessible
Address selector switches are easily accessible
Diagnostic LED is visible
2.
Preferably mount the device to a conductive surface. If this is
impossible, later on connect the second connection point of equipment
grounding conductor at the device to the equipment grounding system
of the installation.
3.
For devices of the "W" and "A" cooling types, only the mounting position
G1 is allowed.
4.
For the dimensions of the mounting holes, see the dimensional drawing
of the device.
5.
Data of the mounting screws:
Devices of "B" or "I" cooling type:
Thread: M5
Tightening torque: 6 Nm
Devices of "A" or "W" cooling type:
Thread: M6
Tightening torque: 6 Nm
Devices of cooling type "B" are mounted on a cold plate.
Required cold plate properties:
See
chapter 9.1.3 "Cold plate" on page
WARNING
Working within the range of live parts is extremely dangerous. Therefore:
Any work required on the electric system may be carried out only by
skilled electricians. It is absolutely necessary to use power tools.
Before starting work, the system must be de-energized and the power
switch be secured against unintentional or unauthorized re-energization.
Before starting work, the appropriate measuring equipment must be
used to check whether parts of the system are still under residual
voltage (e.g. caused by capacitors, etc.). Wait to allow the system to
discharge.
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
279.
High electrical voltage! Danger to life by
electric shock!

Advertisement

Table of Contents
loading

Table of Contents