11.5.2

Maintenance of the Electronic System of the Drive

Commissioning, operation, diagnostics and maintenance
For further information on software functions, see Functional Description
of firmware.
The electronic system of the drive (power section and control section)
operates without wear within the given operating conditions and service life.
However, operation under unfavorable conditions (e.g. increased ambient
temperature) can lead to limitations in availability.
CAUTION
After switching the devices off, wait 15 minutes to allow them to cool down
before touching them. Do not work at hot surfaces.
In regular intervals (at the latest, after one year is over), check the heat sink
of the electronic system of the drive for accumulated dirt (e.g. dust deposits).
Remove accumulated dirt.
Risk
of
burns
by
hot
temperatures of more than 60 °C!
R911335703_Edition 04 Bosch Rexroth AG
363/407
surfaces