Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual page 182

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

168/407
Connection points
Unused output coupling
Principle of output coupling
Bosch Rexroth AG R911335703_Edition 04
If you do not use the communication output coupling, connect X108 and
X109 to the
RKB0043
cable. Otherwise, the communication in the drive line
is interrupted. The HAS10.1-001-002-NN accessory is used to fasten the
cable to the device.
Fig. 6-9:
Cable for unused output coupling
In the case of devices with communication output coupling, the
communication signals are transmitted to the connection points X108 and
X109 via a circuit board (see figure: LK_A). If neither a component nor the
RKB0043
cable has been connected to X108 and X109, the communication
in the drive line is interrupted.
ext
External component or
int
Internal signal processing
LK_A
Internal circuit board for communication output coupling
X_serc
Internal communication interface
Fig. 6-10:
Devices with communication output coupling
In the case of devices without communication output coupling, the
communication signals are directly transmitted via a circuit board (see figure:
LK_B).
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
RKB0043
cable

Advertisement

Table of Contents
loading