Knk03 Mains Filter; Knk03 Data Sheet - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
5.7

KNK03 mains filter

5.7.1

KNK03 data sheet

Description
Degree of protection according to
IEC 60529
Listing in accordance with UL
standard
Listing in accordance with CSA
standard
Mass
Three-phase mains voltage at TN-
S, TN-C, TT mains
Mains voltage, three-phase at IT
mains
2)
Mains voltage, three-phase at
Corner-grounded-Delta mains
Tolerance rated input voltage U
Mains input contin. current
Typical inductance per winding at
I
cont
Power dissipation at continuous
current and continuous DC bus
power respectively
3)
Allowed leakage capacitance
Allowed Y-capacitance
Insulation resistance at 500 V DC
Required wire size in accordance
with NFPA 79 and UL 508 A
(internal wiring);
4)
Technical data - currents, voltages, power
KNK03.1A-
NR-A0008-P-
Symbol
Unit
U226-A4-
IP
m
kg
U
V
LN
U
V
LN
U
V
LN
%
LN
I
A
L_cont
L
µH
typ
P
W
Diss_cont
C
nF
Abl
C
nF
Y
R
Mohm
is
A
AWG
LN
1) 2)
Mains voltage > U
point, do not use autotransformers!
3)
Plus dissipation of braking resistor and control section
4)
Copper wire; PVC-insulation (conductor temperature 90 °C;
T
≤ 40 °C) in accordance with NFPA 79 chapter 12 and
a
UL 508A chapter 28
Tab. 5-17:
KNK - Technical data - currents, voltages, power
Technical data of the components
KNK03.1A-
NR-B0012-P-
U226-A4-
NNNN
NNNN
IP65
UL 61800-5-1
CSA C22.2 No. 274-13
24.00
20.00
AC 380...500
AC 380...500
Not allowed
±10
8.1
12
2.3
147
175
226
2200
> 1
14
Latest amendment: 2019-08-08*
: Use a transformer with grounded neutral
LN
R911335703_Edition 04 Bosch Rexroth AG
105/407
KNK03.1A-
KNK03.1A-
NR-I0002-P-
NR-W0010-P-
U226-A4-
U226-A4-
NNNN
NNNN
24.00
2.3
9.5
104
160

Advertisement