308/407
Accessories
10.8.2

HAS05.1-021-NCN-NN

Bosch Rexroth AG R911335703_Edition 04
Fig. 10-7:
HAS05.1-021-NCN-NN, hybrid joint with 42 V connection (X37)
The accessory is a very short hybrid cable and connects two devices
mounted side by side.
Hybrid cable with communication
Distance, connector center – connector center: 62 ... 87 mm
Degree of protection IP65
M12 female connector (X37) to connect an additional 42 V power supply
Control voltages galvanically isolated between the zones before
and after the accessory
Allowed current: 15 A
Degree of protection: IP65
External power supply required (42 V
"CPS20.361" (100‑240 V, 480 W) or "QT20.361" (380‑480 V,
480 W)
Material number: R911392277
The accessory allows the drive line to be expanded by more components, if
one of the following conditions applies:
Power of the DC/DC converter (24V/42V) in KCU or KMV has already
been used to capacity (e.g., due to many motors with integrated holding
brakes)
Voltage drop on the control voltage lines in the hybrid cable has reached
its allowed limit (e.g., due to long cables)
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
, ±10%; e.g., PULS