220/407
Notes on project planning
7.1.7

KCU02 drive connection box

General information

Functions
Arrangement

Control voltage supply

Control voltage KCU, KSM, KMS
Bosch Rexroth AG R911335703_Edition 04
The drive connection box KCU mainly fulfills the following functions:
Transmitting the power supply to the drive line
42V supply of the KSM/KMS in the drive line
Transmitting the communication signals to the drive line
Exchanging status signals between motors and supply unit
Displaying the status signals of the drive line for diagnostic purposes
The KCU drive connection box is arranged next to the supply unit or next to
other axes mounted between supply unit and KCU. Axes with a high degree
of power consumption should be arranged as near as possible to the supply
unit.
The KCU drive connection box needs 24V supply for operation. From the
applied 24V supply,
KCU supplies itself and
at "X53, control voltage output" generates the 42V control voltage for
the KSM/KMS in the drive line.
BR
Circuit for brake control
I/O
Inputs/outputs
int.
Internal electronics
KCU
Drive connection box
KMS
Near motor servo drive
KSM
Motor-integrated servo drive
Fig. 7-3:
Control voltage KCU, KSM, KMS
At a KCU, it is permitted to operate KSM/KMS with and without integrated
holding brake (observe allowed number of axes and cable length). The load
at X53 should not exceed the value of P
In operation under rated conditions, the sum of P
at the "control voltage supply +24V, 0V" input of KCU as load for the 24V
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
(see
technical data of
out
and P
out
KCU).