14.2

Digital outputs

14.2.1

Digital outputs (safety technology L options)

The digital outputs are compatible with digital inputs of types 1, 2 and 3
(IEC 61131).
Fig. 14-3:
Symbol
Data
Supply voltage (U
)
ext
Current consumption (I
)
ext
Output voltage ON
Output voltage OFF
Output current ON
Allowed energy content of
connected inductive loads, e.g.
relay coils; only allowed as
single pulse
Short circuit protection
Overload protection
Tab. 14-5:
Digital outputs (safety technology L options)
Unit
Min.
V
19,2
mA
V
18,2
V
mA
mJ
Available
Available
R911335703_Edition 04 Bosch Rexroth AG
371/407
Appendix
Max.
30
700
30
5
350
400