X118, X119, External Communication - Bosch rexroth IndraDrive Mi KCU02 Project Planning Manual

Drive systems
Hide thumbs Also See for rexroth IndraDrive Mi KCU02:
Table of Contents

Advertisement

170/407
Connection points
6.3.6

X118, X119, external communication

View
Female connector M12 (5‑pin, D‑coded)
Ready-made connection cable
Bosch Rexroth AG R911335703_Edition 04
The optional connection point X118/X119 is a Multi-Ethernet interface used to
connect
components
PROFINET IO, EtherNet/IP, EtherCAT, POWERLINK) in distributed form.
X118, X119
Connection
Signal name
1
2
3
4
5
RKB0043
(M12 → M12)
RKB0044
(M12 → RJ-45)
Tab. 6-26:
X118, X119; function, pin assignment, properties
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
with
Ethernet-based
communication
Function
Tx+
Transmit, Differential Output A
Rx+
Receive, Differential Input A
Tx-
Transmit, Differential Output B
Rx-
Receive, Differential Input B
Shield
Shield connection
(Only use shielded cables for which the
shield has been connected to ground
over the largest possible surface area via
the housing.)
(Sercos,

Advertisement

Table of Contents
loading

Table of Contents