Panasonic LP-GS Series Operation Manual page 199

Laser marker navi smart
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

1
2
3
4
5
6
7
8
(1) "Column", "Start column": 2, "Last column": 4
(2) "Single step", "Start row": 8, "Start column": 8
(3) "Row", "Start row": 4, "Last row": 6
(4) "Rectangle range", "Start row": 1, "Last row": 2, "Start column": 6, "Last column": 9
You can specify different parameters to correct the marking position.
The following figure shows these parameters.
+
(5)
(1) X-movement
(2) Y-movement
(3) Z-movement
(4) Rotation (-)
(5) Rotation (+)
" X-movement [mm]", "Y-movement [mm]":
Enter a value to move the selected element of the step & repeat object along the x-axis
and y-axis.
" Z-movement [mm]" (LP-GS except LP-GS051-L):
Enter a value to position the selected element of the step & repeat object along the z-
axis.
"Rotation movement [°]":
Specify an angle to rotate the selected element of the step & repeat object.
The rotation center is the reference point of the original marking object.
Correct the laser power:
"Laser power correction [+/-%]":
To correct the laser power of the selected element, enter a value in the text box. You can
enter a correction value between -50% and +50%.
ME-NAVIS2-OP-1
1 2 3 4 5 6 7 8 9
(1)
(2)
(3)
(4)
(3)
(2)
-
(4)
(1)