E618
Cause:
The workpiece spacing is too small.
Remedy:
For marking at regular intervals, increase the workpiece spacing.
For multiple trigger mode, increase the time between trigger signals.
Decrease the line speed.
Specify an upstream position (positive value) for the lasing start
boundary.
For multiple trigger mode, make sure the switch or the sensor
connected to TRIGGER IN (X5) of the TERMINAL connector
operates without chattering.
Reduce the marking time by increasing the scan speed, reducing the
space between characters, reducing the character size, reducing the
ON-time for one-shot outputs, etc.
Applies to LP-RC, LP-RF, LP-RV only.
E619
Cause:
On-the-fly marking is not possible with the set trigger detecting position
or lasing start boundary.
Remedy:
Place the lasing start boundary downstream of the trigger detecting
position.
Check the setting of the workpiece reference boundary.
Applies to LP-RC, LP-RF, LP-RV only.
E620–E621
Cause:
The processing in the laser marking system could not be completed.
Marking trigger processing terminated abnormally.(Applies to the linking
of image processing devices.)
Remedy:
Check the connection of cables and signal lines, and restart the laser
marking system.