Specify Profinet Communication Settings - Panasonic LP-GS Series Operation Manual

Laser marker navi smart
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

24 System settings
4.
Select "Apply to laser marking system" in the ribbon.
5.
Disconnect the online connection with the laser marking system.
6.
Turn off the power of the laser marking system, wait five seconds and then restart the
system.
The new settings will be updated in the laser marking system.
Related topics
Specify remote mode settings

24.18 Specify PROFINET communication settings

If you are using the optional PROFINET network unit, configure the communication settings.
PROFINET communication is supported by LP-RF and LP-RV.
PROFINET communication should be performed in a secure network environment.
270
"Explicit message data size [byte]":
Specifies the maximum size of the explicit message. Check the specification of your
PLC and set a value that can be accepted by the PLC.
Setting range: 64–1448 bytes
Initial setting: 300 bytes
"Control method of input signals":
To open the settings dialog, select "Open settings".
Specify the control method for inputs on the TERMINAL connector and I/O
connector. Select "I/O" (initial setting) or "EtherNet/IP".
Select "I/O to all" or "EtherNet/IP to all" to change the control method for all inputs at
once.
The inputs REMOTE INTERLOCK IN, INTERLOCK 1 and INTERLOCK 2 cannot be
controlled via EtherNet/IP.
For the following inputs, settings are activated if the control method is set to "I/O" in
"System settings" > "Operation/information".
‒ REMOTE IN (remote mode switching method)
‒ LASER SUPPLY IN (laser pumping control)
‒ SHUTTER IN, SHUTTER ENABLE IN (shutter control)
‒ GUIDE IN (guide laser control)
Select "OK" to close the dialog.
Do not turn off the power supply during an online connection with your PC. Otherwise a data loss or
system failure may occur.
(page 257)
ME-NAVIS2-OP-1