E674
Cause:
A string containing "%" is not properly set.
Remedy:
If functional characters such as a counter or date/time are input,
delete and re-enter the characters after "%".
To mark the character "%", enter "%%".
To mark the character "+" or "/" after a counter, enter "%+" or "%/".
E678
Cause:
The character number specified by the SIN command has not been set
in Laser Marker NAVI smart.
Remedy:
Specify the same character number in Laser Marker NAVI smart and in
the SIN command.
E679
Cause:
Communication was interrupted. Power optimization by marking position
could not be applied.
Remedy:
Set the value for "Power optimization by marking position" and apply
the setting again.
Do not turn off the power while the setting is applied.
Do not turn on remote mode while the setting is applied.
Applies to LP-GS, LP-RC only.
E680
Cause:
The following functions are not available in RUN mode:
"Functional characters" > "External control" > "Registered characters
(via I/O connector)"
"Functional characters" > "External control" > "Characters specified
by SIN command"
"Function settings" > "External offset" (Marking offset via I/O signal or
by SEO command)
"Function settings" > "Counter" > "Reset at date change"
Remedy:
To execute the marking in RUN mode, delete these functions from the
marking data.
The laser marking system must be in remote mode to use these
functions.