E520–E522
Cause:
The marking file or system data were not saved normally when the laser
marking system was turned off. The data of the selected file cannot be
read.
Remedy:
Save the file again in the laser marking system, overwriting the
corresponding file number.
Do not turn off the laser marking system while saving the settings.
E530–E542
Cause:
The marking file or system data were not saved normally when the laser
marking system was turned off. The data of the selected file cannot be
read.
Remedy:
Restore the previously saved backup file.
Do not turn off the laser marking system while saving the settings.
E550–E560
Cause:
A safety function (e.g. interlock or laser stop) was activated during
marking trigger preparation (data transfer to the laser head).
Remedy:
Reset the alarm if laser radiation was stopped by a laser stop signal,
an interlock signal or the "Stop laser" button in "Laser Marker NAVI
smart".
Check if the signal lines are affected by noise.
E570
Cause:
The marking file or system data were not saved normally when the laser
marking system was turned off. The data of the selected file cannot be
read.
Remedy:
Save the file again in the laser marking system, overwriting the
corresponding file number.
Do not turn off the laser marking system while saving the settings.
E571
Cause:
The marking file or system data were not saved normally when the laser
marking system was turned off. The data of the selected file cannot be
read.
Remedy:
Restore the previously saved backup file.
Do not turn off the laser marking system while saving the settings.