Siemens KION Service Manual page 205

Anesthesia workstation
Table of Contents

Advertisement

Diagrams
KION / KION-i – Pneumatic block diagram
CONNEC-
EXP.
PATIENT
EXP.
TED TO
FROM MULTI
MAN.
GAS ANALYZER
PNEU-
UNIT
INSP.
MAN.
MATIC
SECTION
INSP.
N121
P121
FROM MULTI GAS ANALYZER
14
PATIENT
EXP. VALVE
CASSETTE
N126
P126
EXP.
EXPIRATORY
FLOW TRANSDUCER
MAN.
INSP. VALVE
OV12
INSP.
15
15
15
SUPPORT
PLATE FOR
PATIENT CASSETTE
MV5
OUT
IN
CO 2
CANISTER
LID
PATIENT
17
CO 2 ABSORBER
KEY
EMV1
EMV2
EMV3
MANUAL
MV3
MV2
BREATHING
MV4
CPV1
MV1
BAG
OUT
EMV4
IN
19
EMV5
AUXILIARY
MV5
FRESH GAS
SUPPORT PLATE FOR
OUTLET
15
PATIENT CASSETTE
SAMPLING LINE
Color codes used in the block diagram
Color
Gas
Dark green
O
(Oxygen)
2
Grey
Air
Blue
N
O (Nitrous oxide)
2
Yellow
Air/O
2
Light green
O
and Air/N
O
2
2
Light green
O
, Air/N
O and
2
2
with dots
anestetic agent
Orange
O
, Air/N
O and
2
2
anestetic agent
Dark lilac
O
, Air/N
O, CO
, H
O
2
2
2
2
and anestetic agent
Light lilac
O
, Air/N
O, H
O
2
2
2
and anestetic agent
E382 E392E 061 01 02 02
VAPORIZER SECTION
BAG-IN-
16
BELLOWS
BOTTLE
VAPORIZER
POSITION
SELECTION VALVE 1
SENSOR
PC 1766
BREATHING
P114
BELLOWS
N114
APL
VALVE
INTERLOCK
(ONE AT
A TIME)
OV9
OFF
PIVap
MV4
MV1
MV2
MV3
PATIENT
CASSETTE
27
VALVE
CONTROL
AUXILIARY O2 SUPPLY
PC 1755
EXHAUST GAS
P78
P77
N77
N78
FRESH GAS TO VAPORIZER
DRIVE GAS
PATIENT UNIT CABLE
FRESH GAS
26
WATER
SUCTION
23
SUCTION
TRAP
EQUIPMENT
BOTTLE
TO MULTI GAS
ANALYZER
Explanation
O
supply.
2
Air supply.
N
O supply.
2
Drive gas. Normally Air, but O
if the Air supply fails.
2
Fresh gas to vaporizer.
Fresh gas from vaporizer. Pressurized by the
Fresh Gas Pressure Container.
Fresh gas. Regulated by the Inspiratory Fresh Gas Valve.
Expired gas from the patient. Can be used for rebreathing.
Rebreathing gas purified by the CO
Absorber.
2
25
BACKUP GAS
N2O
AIR
VAPORIZER
12
MAGAZINE
P
P
VAPORIZER
VAPORIZER
REG
SV5
OV
5
5
OV
6
SELECTION VALVE 2
SELECTION VALVE 3
650 kPa
MUSHROOM VALVE CONTROL GAS SUPPLY
ACTIVE
O2 SUPPLY
INSTANT O2 SUPPLY
AIR SUPPLY
OV11
OV10
FRESH GAS FROM VAPORIZER
EXHAUST GAS
OFF
8
*
PC 1796
INTERCONNECTION
P70
N70
13
10
PC 1737
MEASURING
PIVap
PIVap
P69
N69
PC 1730
9
MUSHROOM VALVE CONTROL GAS SUPPLY
CONTROL
P68
N68
O2 SUPPLY
N47
P47
PEEP
INSTANT O2 SUPPLY
7
VALVE
INSTANT O2 PATIENT SUPPLY
*
PC 1797
FRESH GAS FLOW
P40 - P43
INSTANT
18
O 2 SUPPLY
11
*
PC1750 TRANSDUCER
0
O 2 +
O 2 FLUSH
EMERGENCY O 2
5 L/min O 2
PC1781 PC1781
PC1781 PC1781
3
1
P46
N46
PEEP
CONNECTED
EXP.
P122
AT TOP OF
INSP.
N122
PATIENT
CASSETTE
N45
SV8
P45
-3.5 kPa
FRESH GAS
SUCTION
INSTANT O2 PATIENT SUPPLY
EJECTOR
FRESH GAS TO VAPORIZER
DRIVE GAS
FROM MULTI GAS
GAS
ANALYZER
OUTLET
5
28
Refers to section number in chapter Description of functions.
*
Details of this block can be different on older KION Systems. Refer to chapter Description of functions.
The mushroom valves
MV1 - MV5 control the gas
flow (vertical direction in
the diagram) in the patient
cassette. Gas flow around
the mushroom valves is
always unrestricted.
Actual
Controller symbol
used in these
Desired
diagrams.
Siemens-Elema AB
SUPPLY MANIFOLD
O2
O2
P
REG
REG
SV6
OV
8
SV7
6
OV
7
7
650 kPa
650 kPa
O2
AIR
N2O
P55 N55
FRESH GAS
SV3
PRESSURE CONTAINER
18
8 - 15 kPa (80 - 150 mbar)
kPa
P44
100
N44
P71
N71
P113
PC 1752
REG
3
kPa
6
POSITION
SENSOR
INSPIRATORY
P36
CONTROL
N36
N49
P49
N72
N130
P130
INSPIRATORY
SV1
600
FRESH GAS
2
4
kPa
N50 P50
VALVE WITH
PC1751
P73
STEP MOTOR
P120
N120
PC 1765
GAS MODULE AIR (N 2 O) - BP
PC 1765
MAN.
N48
P48
VALVE INTER-
CONNECTION
N53 P1
GAS MODULE O 2 - BP
OV4
N52 P1
GAS MODULE DRIVE GAS AIR (O 2 )
SV4 14 kPa
N51 P1
SV2
14
kPa
INSPIRATORY GAS BLOCK
23
KION / KION-i
GAS DISTRIBUTION BLOCK
5
PS3
PC 1720
WALL
O2
PRES-
PS2
SURE
AIR
O 2
PS1
N80
P80
N2O
P81
O2
N81
OV1
AIR
AIR
O2 SUPPLY
OV2
AIR SUPPLY
N2O
OV3
N 2 O
28
EVAC
EMV 6
EMV 7
REG
20
REG
320
1
kPa
2
*
kPa
AIR (N2O)
O2
DRIVE GAS SUPPLY
PNEUMATIC
SECTION
9
9 - 23

Advertisement