Important

Important
General
1
• Service documentation for the KION™ / KION-i™
anesthesia workstation consists of:
– Operating Manual. The Operating Manual is an
indispensable complement to the Service
Manual for proper servicing.
– Service Manual
– Installation Instructions
– Spare Parts information
– Documentation for the KION / KION-i Monitor.
– Documentation for all optional equipment
included in the KION / KION-i workstation.
• The following conventions are used throughout
this Service Manual:
– KION represents KION anesthesia workstation.
– KION-i represents KION-i anesthesia
workstation.
• The information in this Service Manual is based
on:
– KION version 7.x.
– KION-i version 10.x.
The information in this Service Manual is valid for
both versions unless otherwise stated.
• Serial number of the unit is found on a label
attached by the mains power inlet.
• A system version label is found by the mains
power inlet. Make sure that the version of the
Operating Manual corresponds to this system
version.
Text inside a box is used to highlight important
information.
• In addition to the Important information given
here and in the related documents (e. g. in the
Operating Manual), always pay attention to
applicable local and national regulations.
• Responsibility for the safe functioning of the
equipment reverts to the owner or user in all
cases in which service or repair has been done by
a non-professional or by persons who are not
employed by or authorized by Siemens, and
when the equipment is used for other than its
intended purpose.
1 - 2
Symbols used in this manual
• ESD sensitive components. When
handling ESD-sensitive devices,
established procedures must be
observed to prevent damage.
• Special waste. Discard disposable,
replaced and left-over parts in accor-
dance with appropriate industrial and

environmental standards.

• Recycling. Recycle if possible.
Recycling facilities may not be
available in all areas.
• Technical training. Refers to the
Technical training supplied by
Siemens.
• Service contract. Refers to the
Service contract supplied by
Siemens.
Hazard notices
• Before disassembling or assembling, make sure
that:
– Gas supply is disconnected.
– Mains power cable is disconnected.
– Power switch is set to Off. If the power switch
is set in any other position, the internal battery
will supply power to the PC boards.
– The internal battery is disconnected when the
power section is open.
– All gas conveying parts are cleaned according
to instructions in the KION / KION-i – Operating
Manual, chapter Routine cleaning.
• With power supply connected to the KION /
KION-i workstation, there are energized electrical
components inside the unit. All personnel must
exercise extreme caution if fault tracing or
adjustments are performed with power supply
connected and with user interface and patient
unit covers removed.
Installation

• Only personnel trained and authorized

by Siemens shall be permitted to

install the KION / KION-i workstation.
The installation and handing-over
procedures are described in the
"Installation Instructions".
Siemens-Elema AB
KION / KION-i
E382 E392E 061 01 02 02