Figure 6-29: Restart Totalflow device after public key update
With the key upload complete, a new private-public key pair is available for authentication. Test the
authentication with these new keys next.
6.7.3.4
Verify authentication with new private-public key pair
Verify that the public key update successfully established a new FileZilla SFTP connection with the new
key and passphrase.
To verify:
1.
Restart FileZilla.
2.
Click Open the Site Manager. The Site Manager window displays.
3.
Configure the General tab:
Host: Type the device's IP address.
Port: Type 9696.
Protocol: Select SFTP- SSH File Transfer Protocol from the drop-down list.
Logon Type: Select Key file from the drop-down list.
User: Type the user required per account type (For the Totalflow user account, type
totalflow. For the developer or tech-support accounts, type "root".)
4.
Click Browse to locate and select the newly created private key.
5.
Click Connect.
6.
Type the private key passphrase into the passphrase prompt. FileZilla displays the device's file
system directories.
IMPORTANT NOTE: Keep private key files stored in a safe location accessible only to authorized
personnel and security managers.
7

Calibration

Calibrate the controller onboard analog inputs and outputs to support different types of external
devices, measurement ranges, and engineering units.