Toshiba GRL100-701B Instruction Manual page 201

Grl100-7**b series. line differential relay
Table of Contents

Advertisement

4.2.4.2
Displaying the Status of Binary Inputs and Outputs
To display the binary input and output status, do the following:
• Select 2 (=Status) on the top "MENU" screen to display the "Status" screen.
• Select 2 (=Binary I/O) to display the binary input and output status.
/ 2
I n p u t
I n p u t
I n p u t
I n p u t
O u t p u t ( I O 1 - t r i p )
O u t p u t ( I O # 2
O u t p u t ( I O # 3
O u t p u t ( I O # 4
The display format of IO and FD modules is shown below.
[
Input (IO#1)
BI1
BI2
Input (IO#2)
BI16 BI17 BI18
Input (IO#3:IO5)
BI19 BI20 BI21 BI22 BI23 BI24 BI25 BI26 BI27 BI28
Input (IO#3:IO6)
BI19 BI20 BI21 BI22 BI23 BI24 BI25
Input (IO#4:IO4)
BI34 BI35 BI36
Output (IO#1-trip) TPA1 TPB1 TPC1 TPA2 TPB2 TPC2
Output (IO#2)
BO1 BO2 BO3 BO4 BO5 BO6 BO7 BO8 BO9 BO10 BO11 BO12 FAIL BO13
Output (IO#3:IO3) BO1 BO2 BO3 BO4 BO5 BO6 BO7 BO8 BO9 BO10
Output (IO#3:IO5) BO1 BO2 BO3 BO4 BO5 BO6 BO7 BO8 BO9 BO10
Output (IO#3:IO6) BO1 BO2 BO3 BO4 BO5 BO6
Output (IO#4:IO4) BO1 BO2 BO3 BO4 BO5 BO6 BO7 BO8 BO9 BO10 BO11 BO12 BO13 BO14
Lines 1 and 2 show the binary input status. BI1 to BI18 correspond to each binary input signal.
For details of the binary input signals, see Appendix G. The status is expressed with logical level
"1" or "0" at the photo-coupler output circuit. The module names of IO#1 to IO#4 in the table
depend on the model. (Refer to Appendix G.)
Lines 5 to 12 show the binary output status. TPA1 to TPC2 of line 5 correspond to the tripping
command outputs. Other outputs expressed with BO1 to BO14 are configurable. The status of
these outputs is expressed with logical level "1" or "0" at the input circuit of the output relay
driver. That is, the output relay is energized when the status is "1".
To display all the lines, press the
4.2.4.3
Displaying the Status of Measuring Elements
To display the status of measuring elements on the LCD, do the following:
• Select 2 (=Status) on the top "MENU" screen to display the "Status" screen.
• Select 3 (=Relay element) to display the status of the relay elements.
B i n a r y
i n p u t
&
( I O # 1
)
( I O # 2
)
( I O # 3
)
( I O # 4
)
#
)
)
)
BI3
BI4
BI5
BI6
and
 200 
o u t p u t
[ 0 0 0
0 0 0
0 0 0
[ 0 0 0
[ 0 0 0
0 0 0
0 0 0
[ 0 0 0
[ 0 0 0
0 0 0
[ 0 0 0
0 0 0
0 0 0
[ 0 0 0
0 0 0
0 0 0
[ 0 0 0
0 0 0
0 0 0
BI7
BI8
BI9
BI10 BI11 BI12 BI13 BI14 BI15
keys.
6 F 2 S 0 8 5 0
3 /
8
0 0 0
0 0 0 ]
]
0
]
]
]
0 0 0
0 0
]
0
]
0 0 0
0 0
]
]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grl100-702bGrl100-711bGrl100-712b

Table of Contents