No.
Signal Name
241
242
243
244
245
246
247
248
249
250
251 CHECKING
252 CHK FAIL-Q
253 CHK STEP1
254 CHK_STEP2
255 CHK_STEP3
256 OC/OCI_TRIP
257 EF/EFI_TRIP
258 RYIDSV1
259 RYIDSV2
260
261 TRIP-H
262
263 DEG ALARM
264 AMP ALARM
265 DEG_OK
266 CF1
267 CF2
268 TDSV1
269 TDSV2
270 50/60Hz
271 1PPS_OFF
272 1PPS_SV-L
273 1PPS_SV-R
274 1PPS_ERROR
275
276
277
278
279 DIF#1_
280 DIF#2
281 DIF-A#1
282 DIF-B#1
283 DIF-C#1
284 DIFG#1
285 DIF-A#2
286 DIF-B#2
287 DIF-C#2
288 DIFG#2
289 OVER_PH
290 INVALID_PH
291 UNDER_PH
292
293
294
295 MODE2A
296
297
298
299
300
301 OCMF-L1
302 OCMF-L2
303 OCMF-L3
304 OCMF-L4
305 OCMF-L5
306 OCMF-L6
307 OCMF-L7
308 OCMF
309 OCDF-A
310 OCDF-B
311 OCDF-C
312 OVL-A
313 OVL-B
314 OVL-C
315
316 EFF
317 UVSF-AB
318 UVSF-BC
319 UVSF-CA
320
During automatic checking
Fail-to-operate of tripping output circuit
Checking step1
Checking step2
Checking step3
OC/OCI trip
EF/EFI trip
RYIDSV1 (Remote 1 relay address monitoring)
RYIDSV2 (Remote 2 relay address monitoring)
Trip signal hold
DEG ALARM output
AMP ALARM output
DEG OK output
Telecommunication failure detect signal for ch#1
Telecommunication failure detect signal for ch#2
Telecommunication delay time over of ch#1
Telecommunication delay time over of ch#2
Pulse signal for end-to-end test
1PPS signal check (instant)
1PPS signal check for a certain time at local term.
1PPS signal check for a certain time at remote term.
1PPS signal interval error
ch2 used for sampling synchoronization
DIF#1 element block signal
DIF#2 element block signal
DIF-A#1 element output
DIF-B#1 element output
DIF-C#1 element output
DIFG#1 element output
DIF-A#2 element output
DIF-B#2 element output
DIF-C#2 element output
DIFG#2 element output
Phase difference (over)
Phase difference (invalid)
Phase difference (under)
Synchronization in MODE2A
OCMF-L1 element output
OCMF-L2 element output
OCMF-L3 element output
OCMF-L4 element output
OCMF-L5 element output
OCMF-L6 element output
OCMF-L7 element output
OCMF element output "OR"
OCDF-A element output
OCDF-B element output
OCDF-C element output
OVL-A element output (for 3phase line voltage)
OVL-B element output (for 3phase line voltage)
OVL-C element output (for 3phase line voltage)
EFF element output
UVSF-A element output
UVSF-B element output
UVSF-C element output