ABB i-bus KNX Product Manual page 68

Blind/roller shutter actuators jra/s
Hide thumbs Also See for i-bus KNX:
Table of Contents

Advertisement

ABB i-bus
KNX
Start-up
Limit travelling range
Options:
For certain applications, the traveling range of the blind/shutter can be limited for the user.
Note
The restriction only works with a telegram to the communication object Blinds/shutter up-down limited
and with a scene telegram.
The restriction does not apply to:
Via object "Blinds/shutter up-down limited": The communication object Blinds/shutter up-down limited
is enabled. The following parameters appear:
Via object "Enable limitation": The communication object Enable limitation is enabled. If the restriction
was activated via the communication object, then the blind/shutter will move within the specified limits.
The following parameters appear:
66 2CDC 506 051 D0204 | JRA/S
No
Via object "Blinds/shutter up-down limited"
Via object "Enable limitation"
Reaction on bus voltage failure, recovery, download and ETS reset
Safety functions (Weather alarms, Block and Forced operation)
Manual operation
Automatic telegrams
Parameter setting Move to position via lower/upper end position
Reference movement or travel detection
Upper limit in % [0...100]
(0% = top; 100% = bottom)
Lower limit in % [0...100]
(0% = top; 100% = bottom)
Options:
0...100
These parameters define the upper and lower limit of the travel range.
Upper limit in % [0...100]
(0% = top; 100% = bottom)
0...100 %
Options:
This parameter specifies the upper limit of the travel range.

Advertisement

Table of Contents
loading

Table of Contents