General System Information
46
G8264 Command Reference for ENOS 8.4
The following command displays system information:
show sysinfo
Command mode: All
System Information at 13:24:55 Tue Jul 14, 2015
Time zone: No timezone configured
Daylight Savings Time Status: Disabled
Lenovo RackSwitch G8264
Switch has been up for 4 days, 19 hours, 37 minutes and 25 seconds.
Last boot: 17:48:02 Thu Jul 9, 2015 (Software reset)
MAC address: 08:17:f4:ae:b4:00 IP (If 1) address: 192.168.49.50
Management Port MAC Address: 08:17:f4:ae:b4:fe
Management Port IP Address (if 128): 10.241.37.168
Hardware Revision: 0
Hardware Part No: BAC0006500
Switch Serial No: MY2130025W
Manufacturing date: 11/30
MTM Value: 7159HC3
ESN: 1234567
Software Version 8.4.1.0 (FLASH image1), active configuration.
Boot kernel version 8.4.1.0
USB Boot: disabled
Temperature Mother Top : 33 C
Temperature Mother Bottom : 37 C
Temperature Daughter Top : 32 C
Temperature Daughter Bottom : 36 C
Temperature Switch Asic Max : 49 C
System Warning at 75 C / Shutdown at 90 C / Set Point is 65 C
Fan 1 Module 1: 7356rpm 80pwm( 5% bias:65) FrontToBack
Fan 2 Module 1: 4981rpm 80pwm( 5% bias:65) FrontToBack
Fan 3 Module 2: 7438rpm 80pwm( 5% bias:65) FrontToBack
Fan 4 Module 2: 4967rpm 80pwm( 5% bias:65) FrontToBack
Fan 5 Module 3: 7387rpm 80pwm( 5% bias:65) FrontToBack
Fan 6 Module 3: 4963rpm 80pwm( 5% bias:65) FrontToBack
Fan 7 Module 4: 7458rpm 80pwm( 5% bias:65) FrontToBack
Fan 8 Module 4: 4990rpm 80pwm( 5% bias:65) FrontToBack
System Fan Airflow: FrontToBack
Power Supply 1: FrontToBack [DS4503_REV02.XM]
Power Supply 2: FrontToBack [DS4503_REV02.XM]
Power Faults: None
Fan Faults: None