696
G8264 Command Reference for ENOS 8.4
Table 394.
Boot Stacking Options (continued)
Command Syntax and Usage
reload [master|nodump|staggered [delay <2‐20>]|switch
<configured switch number (1‐8)>]
Reboots the switch. You can specifiy one of the following options:
master reboots only the master switch
nodump reboots the switch without saving technical support information
staggered reboots the whole stack one switch at a time, starting with the
backup switch, followed by the master switch and then the other members
of the stack. The delay option configures the time, in minutes, between
each switch reboot.
switch reboots only the specified configured switch
Note: The optional command elements are available only on the master
switch.
Command mode: Privileged EXEC
show boot stack [master|backup|<attached switch number (1‐16)>|
|all]
Displays current Stacking boot parameters.
Note: The optional command elements are available only on the master
switch.
Command mode: All